Request the new Trayco catalogue in 1 click!

Hinged cover sq. carpet edge

HC-CE-SQ-260-SS

Bottom frame (with carpet edge) + cover + cable exit + fixation screws
Max. load small surface: 2000N
Max. load large surface: 3000N
In use: IP20
Not in use: IP30
Standard cover recess depth: 15 mm
Material: SS304
Application: dry-cleaning areas

SKU Article code Finishing Packaging
15957
FS-HC15-CE-SQ-260-SS304
SS304
1
Default
EAN
5415129057920

Assembly

Workload

Norm
Volgens EN50085
Safe workload
-
Max. torque
-

Additional information

Product features
Bottom frame (with carpet edge) + cover + cable exit + fixation screws
Max. load small surface: 2000N
Max. load large surface: 3000N
In use: IP20
Not in use: IP30
Standard cover recess depth: 15 mm
Material: SS304
Application: dry-cleaning areas

EN50085 compliant.
Hinged cover with integrated opening lever.
Equipotential connection provided between cover and frame.
Full INOX-look (no visible synthetic components).
Can be fitted with:
- 1x apparatus cup low height (FS-AC-LOW-260-PG).
or
- max. 3x horizontal apparatus cup (FS-AC-HO-260-PA9011).
Can be fitted directly to the green adjustment frame on the floorbox, ensuring perfect alignment with the finishing floor.
For fitting into raised floor, see HC-CE-SQ-260-RF-SS.
After fixation, the upper side of the carpet edge sticks out 3mm above the adjustment frame.
Equipotential connection
-
EC declaration of conformity
We declare that our products are in conformity with:
- the rules of the essential requirements of the EC directive: 2014/35/EU (low voltage)
- the applicable national standards and technical specifications: CEI IEC 61537

Technical documentation is available at the manufacturer location.

(On condition that the products are used in the manner intended and/or in accordance with the current installation standards and/or with the recommendations of the manufacturer.)

Finishing

Stainless steel (1.4301) AISI 304

Adding chrome(±13%) to the iron creates a certain sheen and the metal becomes more corrosion-resistant.
The advantage, compared to other protective coatings, is that it’s not a one-off surface protection. In fact, the stainless steel (or rather the chrome) forms a thin, invisible layer of chromium oxide whenever it comes into contact with oxygen: the oxide film. This thin layer protects the underlying stainless steel from further corrosion (oxidation). If the oxide flm suffers damage, then the underlying stainless steel will be re-exposed to the oxygen in the air and the protective coat will re-form. In this way, it repairs itself whenever it gets damaged.
In certain circumstances or if the protective oxide flm is damaged, the corrosion can be locally quite rapid. This is caused, among other things, by chlorides or other materials (usually iron) that lodge in the surface. Due to this contamination, pitting corrosion may occur that corrodes the stainless steel (SS). That’s why, after the processing, the SS is treated, to remove all possible impurities. This is the `pickling’ stage.
As mentioned above, a passive chromium layer protects the steel and repairs itself automatically. There are, however, circumstances in which this repair does not happen. Certain process steps may disrupt the balance in such a way that the passive state disappears and an active layer is formed. This could occur during process steps such as welding, bending or machining (with removal of metal or wood), giving rise to oxygen-poor pockets and the repair fails to materialise. Consequently, the rustproof properties are lost and, if exposed to gases or liquids, corrosion will occur.
To remedy this situation, the active layer is re-converted to a passive layer (this process is known as passivating). In is usually desirable to degrease the semi-fnished products and, after that, to pickle them in a mixture of nitric acid (HNO3) and hydrogen fluoride (HF), in order to remove impurities from the metal surface. This may be necessary on welded surfaces or on rotated objects for which a coolant is used.
EN50085 compliant. Hinged cover with integrated opening lever. Equipotential connection provided between cover and frame. Full INOX-look (no visible synthetic components). Can be fitted with: - 1x apparatus cup low height (FS-AC-LOW-260-PG). or - max. 3x horizontal apparatus cup (FS-AC-HO-260-PA9011). Can be fitted directly to the green adjustment frame on the floorbox, ensuring perfect alignment with the finishing floor. For fitting into raised floor, see HC-CE-SQ-260-RF-SS. After fixation, the upper side of the carpet edge sticks out 3mm above the adjustment frame.

Assembly